VCD-SERIES CO2 ADSORBER SPECIFICATIONS Outlet Flow Capacities at Various Operating Pressures |
|||||||||||
| Model | Outlet Flow (liters/minute) | ||||||||||
| PSIG | 50* | 60* | 70* | 80* | 90 | 100 | 110 | 120* | 130 | 140 | 150 |
| VCD3 | 5 | 9 | 13 | 15 | 19 | 23 | 25 | 30 | 33 | 35 | 38 |
| VCD4 | 16 | 26 | 33 | 37 | 48 | 60 | 65 | 73 | 85 | 93 | 99 |
| * factory selected purge orifice installed for these pressures – please state operating pressure with order | |||||||||||
| Model | VCD3 | VCD4 |
| Flows at 100 PSIG (liters/minute) | ||
| Inlet Flow | 40 | 95 |
| Purge Flow | 17 | 35 |
| Outlet Flow | 23 | 60 |
| ALL MODELS | ||
| Power requirement: 115/1/50/60 or
220/1/50/60, 20 watts Maximum temperature 120°F ambient Maximum pressure 150 PSIG Outlet CO2 concentration: less than 1 PPM Outlet H2O concentration less than 1 PPM (-100°F dew point) |
||
| RECOMMENDED FILTRATION ON INLET | ||
| Lubricated Compressor: 5.0 Micron
filter and 0.01 Micron filter Non-lubricated Compressor: 5.0 Micron filter |
||

| Connections (NPT) | ||
| Inlet | 1/4" | 1/4" |
| Outlet | 1/4" | 1/4" |
| Dimensions (Inches) | ||
| Height - "A" | 16.1 | 24.1 |
| Width | 8 | 8 |
| Depth | 4.8 | 4.8 |
| Weight (Pounds) | 9 | 14 |