VCD-SERIES CO2 ADSORBER SPECIFICATIONS Outlet Flow Capacities at Various Operating Pressures |
|||||||||||
| MODEL | OUTLET FLOW (liters/minute) | ||||||||||
| VCD3 | 5 | 9 | 13 | 15 | 19 | 23 | 25 | 30 | 33 | 35 | 38 |
| VCD4 | 16 | 26 | 33 | 37 | 48 | 60 | 65 | 73 | 85 | 93 | 99 |
| PSIG | 50* | 60* | 70* | 80 | 90 | 100 | 110 | 120* | 130* | 140* | 150* |
|
* factory selected purge orifice installed for these pressures |
|||||||||||
| MODEL |
VCD3
|
VCD4
|
|
Flows
at 100 PSIG (liters/minute)
|
||
| Inlet Flow |
40
|
95
|
| Purge Flow |
17
|
35
|
| Outlet Flow |
23
|
60
|
|
Connections
(NPT)
|
||
| Inlet |
1/4"
|
1/4"
|
| Outlet |
1/4"
|
1/4"
|
|
Dimensions
(Inches)
|
||
| Height |
16.1
|
24.1
|
| Width |
8
|
8
|
| Length |
4.8
|
4.8
|
| Weight (Pounds) |
9
|
14
|
|
All Models: |
||
|
Power requirement: 115/1/50/60 or 220/1/50/60, 20 watts Maximum temperature 120°F ambient Maximum pressure 150 PSIG Outlet CO2 concentration: less than 1 PPM Outlet H2O concentration less than 1 PPM (-100°F dew point)
Recommended filtration on inlet: Lubricated Compressor: 5.0 Micron filter and 0.01 Micron filter Non-lubricated Compressor: 5.0 Micron filter |
||