VCD-SERIES CO2 ADSORBER SPECIFICATIONS

Outlet Flow Capacities at Various Operating Pressures

MODEL OUTLET FLOW (liters/minute)
VCD3 5 9 13 15 19 23 25 30 33 35 38
VCD4 16 26 33 37 48 60 65 73 85 93 99
PSIG 50* 60* 70* 80 90 100 110 120* 130* 140* 150*

  * factory selected purge orifice installed for these pressures
 - please state operating pressure with order

 

  MODEL
VCD3
VCD4
Flows at 100 PSIG (liters/minute)
  Inlet Flow
40
95
  Purge Flow
17
35
  Outlet Flow
23
60
Connections (NPT)
  Inlet
1/4"
1/4"
  Outlet
1/4"
1/4"
Dimensions (Inches)
  Height
16.1
24.1
  Width
8
8
  Length
4.8
4.8
  Weight (Pounds)
9
14

  All Models:

  Power requirement: 115/1/50/60 or 220/1/50/60, 20 watts 

  • Maximum temperature 120°F ambient

  • Maximum pressure 150 PSIG

  • Outlet CO2 concentration: less than 1 PPM

  • Outlet H2O concentration less than 1 PPM (-100°F dew point)

 

  Recommended filtration on inlet:

  • Lubricated Compressor: 5.0 Micron filter and 0.01 Micron filter 

  • Non-lubricated Compressor: 5.0 Micron filter