MCA Series Miniature CO2 Adsorbers

For Dry, CO2-Free Air to 20.5 lpm

 

MCA Series CO2 Adsorber

PUREGAS' Carbon Dioxide Adsorber-Dryers (MCA Series) are designed to remove CO2 and moisture from compressed air. This dryer uses dual towers with media beds featuring 13X molecular sieve in a pressure swing adsorption process. Adsorbed moisture and CO2 are vented to atmosphere while dry CO2-free air is provided at the outlet port.

The dual tower adsorber/dryer design performs two essential functions in one process eliminating the need for an additional unit, reducing costs. The regenerative design provide continuous clean dry, CO2 free air.

Product Features

  • Reduces CO2 to less than 1ppm
  • Reduces water vapor to less than 1ppm
  • Compact, lightweight design saves space
  • Easy to install
  • Continuous self-regenerative operation
  • Quiet
  • Operating pressure 50 to 120 psig
  • Outlet pressure 0 to 120 psig
  • 115 Volts AC, 6 watts, other voltages available

Typical Applications

  • TOC Analyzers
  • Continuous Emissions Monitoring Systems
  • Environmental Instruments
  • FTIR Spectrometers
  • Gas Chromatographs
  • Laboratory Analyzers

MCA1 MCA2 MCA3 MCA4 MCA5 MCA6
*Flows (lpm) at 100 PSIG
Inlet Flow 2.8 8.8 13.2 17.7 25.1 35.3
Purge Flow 1.2 3.7 5.5 7.8 10.3 14.8
Outlet Flow 1.6 5.1 7.7 9.9 14.8 20.5
*Capacities are based on inlet conditions of 70°F, 100%RH, and normal ambient CO2 levels of approximate 375 ppm
Additional Specifications
Inlet / Outlet Ports 1/8" NPT 1/4" NPT
Power Requirements 115 VAC, Single Phase, 50/60 Hz or 220 VAC, Single Phase, 50/60 Hz
12 or 24 VDC
Maximum Temperature 120°F ambient
Maximum Pressure 120 PSIG
Outlet CO2 Concentration Less than 1 ppm
Outlet Dew Point -100°F atmospheric dew point
Dimensions
Weight 22 oz 24 oz 25 oz 30 oz 35 oz 50 oz
Height 7" 10.3" 8.8" 10.1" 9.5" 11.4"
Width 3.5" 3.5" 4" 4" 5" 5"
Depth 3.3" 3.3" 3.5" 3.5" 3.8" 3.8"

Notes:

RECOMMENDED FILTRATION -

     Inlet: 5.0 Micron Particle Filter and 0.01 Micron Coalescing Filter w/ auto drain

     Outlet: 1 Micron Particle Filter

To Download files, Right-click on the link and select "Save Target As..." or "Save Link As..."




Documentation

MCA Series Specification Sheet

MCA Series Manual




To Download files, Right-click on the link and select "Save Target As..." or "Save Link As..."